mechanical anchor supplementary shear reinforcing as a retrofit technique for hollowcore floors

in 2022 New Zealand society for earthquake engineering conference

Scope and methodology

  • The susceptibility of hollowcore and dycore floor systems to seismic actions has generated a need for cost effective seismic retrofits in this area. 

  • This paper outlines proof-of-concept research on the use of the PYTHON HC fastener as supplementary shear reinforcement in hollowcore floor units.

  • Two full scale, three point bending shear tests and FEA analysis was conducted to assess the impact on hollowcore floor unit shear performance of post-installed PYTHON HC supplementary shear reinforcement.

FINDINGS

  • The full scale three point bending test with PYTHON HC supplementary shear reinforcement installed displayed a substantially greater shear capacity than the full scale as-built test.

  • The retrofit test displayed substantially greater post-failure shear capacity than the as-built test indicating that the use of the PYTHON HC as supplementary shear reinforcing may be able to provide a reliable post-failure, life safely, load path.

  • The displacement increase at failure of the retrofit test was substantially less than the as-built test.

  • The FEA model was in good agreement with the full scale physical testing.